High Efficiency Advanced 4-Sage Combustion

Japan's first

  • 5 minutes from cold start to full pressure.
  • Fuel: Natural gas, LP gas
  • Equivalent evaporation: 750 ~ 2,500 kg / h
  • Operating efficiency improved turn down 1:5
  • Maximum operating pressure: 0.98MPa [G]
  • Boiler efficiency: 98% boiler efficiency

  • Functions and features

  • Four position advanced combustion control boiler life and operating efficiency improved by leaps and bounds
  • More fine-grained control and at least 20% combustion
  • Low noise and low NOx environmentally friendly
  • High efficiency boiler
  • Good quality steam high dryness
  • Space-saving compact case
  • Fuel and electricity bill significant savings
  • Continuous blow equipment standard
  • Function pursuit microcomputer control standard
  • Optional Specifications Related Products

  • Ultra-low NOx (13A gas-fired)
  • High-performance microcomputer control
  • Thermal management device
  • Number of controller
  • Blower inverter control
  • Online guard system
  • Boiler Pressure control

    This is an IHI patented technology, which controls the water
    level for each boiler load. It prevents the overheating in the
    boiler tubes and provides steam with a high degree of dryness.

     

    Eccentric Structure Boiler

    The boiler uses dual evaporation pipes with an eccentric structure. The
    structure is calculated for large volume with high temperature gas and
    low volume with low temperature gas for overall unified heat
    absorption. Furthermore, there is little pressure loss for the gas, which
    also leads to smaller motor power. (K-750to 2000)

    Boiler Water Level Controls (patented)

    This is an IHI patented technology, which controls the water level
    for each boiler load. It prevents the overheating in the boiler
    tubes and provides steam with a high degree of dryness.

     

    Continuous Blowers

    The continuous blowers are a part of the standard equipment in
    the boiler system, which have a capacity starting from 1,600 kg/h
    or higher and serve as a heat exchanger at 50 kW.
    The electromagnetic valve and feed water pump are interconnected ,
    thereby blowing is only performed when water is supplied, which
    increases the heat absorption rate.

     

    Economizer (Standard on the K-SE Series)

    Economizers are sometimes installed to absorb heat from the
    exhaust gas. The IHI economizer provides complete consideration
    towards corrosion resistance, using materials such as SUS316L for
    the heating tubes.

     